Electromagnetic Flow Meter

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-07-19 13:41

  • Browse the number:

    410

Send an inquiries
+
Beijing Sentinain Technology Inc
Contactaixin:

Contactaixin:

shengtian(Mr.)  

Email:

telephone:

phone:

Area:

Beijing

Address:

Room 208-210 Kequn Building, 30 Xueyuan Road, Haidian District, Beijing

Website:

http://www.fermenter-st.com/ http://shengtian.huajin-elec.com/

+
Electromagnetic flow meter




Electromagnetic Flowmeter: SDL-EM20


Magnetic flowmeter details:


1. The principle is virtually independent of pressure, density,temperature and viscosity

2. Superior control through advanced sensor design

3. Even fluids with entrained solids can be metered (e.g. ore slurry, cellulose pulp)

4. Submersible and buriable installation options

5. Intuitive navigation and configuration

6. Free pipe cross-section (CIP/SIP cleaning, piggable)

7. Speed, ease and security in the field

8. No moving parts, Minimum outlay for maintenance and keep

9. Detailed diagnostics for rapid decision making

10. Powerful and flexible transmitter

11. No pressure losses, Very high turndown up to 1000:1

12. High degree of measuring dependability and reproducibility,good long-term stability


Electromagnetic flow measurement has been in use around the world for 50 years and more, as witnessed by the popularity of these meters that continues unabated in virtually all sectors of industry.


The Electromagnetic Flowmeter is the ultimate solution for flow measurement and management and can be used to measureall electrically conductive liquids (> 5 µS/cm) with or without solids, e.g. water, wastewater, sludge, sewage, slurries, pastes,acids, alkalis, juices, fruit pulp, and effluent etc. Its performance adheres to the most stringent global industry standards and is certified to key international approvals.



In the industrial environment, sectors that utilize this measuring principle include: water/wastewater, chemicals,pharmaceuticals, pulp and paper, foodstuffs, etc. Electromagnetic flowmeters are even robust enough to be used in mining.


Proven in the toughest applications, EM20’s rugged, robust and unburnable sensors eliminate the need of expensive meter chambers. Thereby, it provides a long, productive and maintenance-free asset life. Take advantage of its innovative andversatile attributes to achieve interoperability within a wide range of asset management systems.



Electromagnetic flowmeters specification:


Nominal diameter

25, (32), 40, 50, (65), 80, 100, (125), 150, 200, 250, 300, 350, 400, (450), 500, 600, 700, 800, 900,1000, 1200, 1400, 1600

Ambient temperature

-25℃~+60℃

Relative humidity

5%~90%

Power supply

85~265V AC, 47.5~52.5Hz or DC 24V

Consumption

Less than 20W

Accuracy

±0.2%, ±0.3%, ±0.5%

Repeatability

0.07%, 0.1%, 0.17% of the measured value

Current output

4~20mA with electric isolation

Load resistance

0~750Ω

Basic error

Basic error of the measured value plus ±10µA

Frequency output

For forward direction and reverse direction, the maximum frequency can be set between 1~5000Hz. The output is collector of transistor open with galvanic isolation. External power supply should be less than 30V, and maximum current for the collector is 250mA when it works.

Pulse output

For forward and reverse direction. The pulse can be up to 15000 per second. The pulse width is up to 25ms. The output is collector of transistor open with galvanic isolation. External power supply should be less than 30V, and maximum current for the collector is 250mA when it works. Via an inside pull-up resister, frequency and pulse output can use the inner 24V power supply. The maximum current for the collector is 2.3mA when it works.

Display

Display with English and Chinese, five characters for flow rate and ten characters for volume.

Alarm

Two alarms are the collector of transistor open output with galvanic isolation. External power supply should be less than 30V, and maximum current for the collector is 250mA when it works.

Alarm output for the following faults: Empty pipe direction, analog exceeds its range, frequency exceeds its range and the fault for magnetic field excitation.

Status input

Communication serial output with RS485. It has protection for lightning strike.

Damp

2~100s (90%)

Isolation

The isolating voltage should be more than 500V between analog output, pulse (frequency output), alarm and ground.

Sentinain Technology has over 20 years experience in providing electromagnetic flow meter for you. As one of the leading manufacturers and suppliers in China, we are equipped with advanced equipment and technology. Please be free to get the low price equipment from our factory and check the quotation with us.